Flex TPO Enhanced Wind Uplift Manual de usuario Pagina 2

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 3
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 1
8/2012 2
2) Approved Decks (wind speeds to 80 mph)
a) 22 gauge steel
b) Structural concrete (3000 psi)
c) Wood Plank (1 ½ min.)
d) CDX Plywood (5/8min.)
e) OSB (7/16min)
f) Lightweight Insulating concrete over steel deck
3) Approved Decks (wind speeds to 90 mph)
a) 22 gauge steel
b) Structural concrete (3000 psi)
c) Wood Plank (1 ½ min.)
d) CDX Plywood (15/32min.)
e) Lightweight Insulating concrete over steel deck
4) Approved Decks (wind speeds to 120 mph)
a) 22 gauge steel
b) Structural concrete (3000 psi)
c) Wood Plank (1 ½ min.)
d) CDX Plywood (15/32min.)
e) Lightweight Insulating concrete over concrete deck
B. Fastening Criteria:
Mechanically Fastened Roof Systems
1) Wind Speeds to 72 mph.
All decks minimum of 2 perimeter sheets. 8 wide or 10 wide field sheets Fasteners
12 o.c.
2) Wind Speeds to 80 mph.
Structural concrete decks Minimum of 4 perimeter sheets. 8 wide or 10 wide field sheets.
Fasteners 12 o.c.
Steel and Wood Decks Minimum of 3 perimeter sheets. 8 wide or 10 wide field sheets. Fasteners
12 o.c.
3) Wind Speeds to 90 mph.
Structural concrete decks, Steel and approved Wood Decks. Minimum of 3 perimeter
sheets. 8 wide sheets fastened 12 o.c., 10 wide sheets fastened 6 o.c.
4) Wind Speeds to 100 mph.
60 mil minimum membrane thickness.
Structural concrete decks, Steel and approved Wood Decks, Minimum of 2 perimeter
sheets fastened 6 o.c. 8 wide sheets fastened 12 o.c. 10 wide sheets fastened 6 o.c.
Adhered Roof Systems
1) Wind Speeds to 80 mph.
a) Polyisocyanurate Insulation Board (20 psi Min 1 ½ thick) 11 fasteners per 4x 8 board.
Vista de pagina 1